Cut in Range -----> a set of cuts in energy:
(Energy threshold for Gamma, Energy threshold for e-+, ...)
Cut in length | Gamma Energy in PbWO4 | e- Energy in PbWO4 |
---|---|---|
50 micron | 12 keV | 136 keV |
100 micron | 20 keV | 210 keV |
500 micron | 60 keV | 642 keV |
1 mm | 85 keV | 1.13 MeV |
5 mm | 137 keV | 5.34 MeV |
1 cm | 219 keV | 11.5 MeV |
More close to the Geant4 behaviour